Suncloud Energy — Deye Technical Hub
SG01HP3 Three-Phase HV Hybrid · 29.9–50 kW
Hybrid inverter Three-phase HV

SG01HP3 Three-Phase HV Hybrid · 29.9–50 kW

SUN-29.9/35/40/50K-SG01HP3-AU-BM3/BM4

29.9–50 kW

High-voltage three-phase hybrid, 29.9–50 kW. 160–800 V battery for higher efficiency, 100% unbalanced output, 3–4 MPPT and up to 100 A battery current — for larger commercial and utility storage. BM3 frame to 35 kW, BM4 frame for 40–50 kW.

CommercialUtility
Rated AC power
29.9 / 30 / 35 / 40 / 50 kW
Phase
Three (230/400 V, 240/415 V)
Battery
HV Lithium-ion, 160–800 V, up to 50+50 A
Max. PV input power
44.85–75 kW
Unbalanced output
100%
Max. efficiency
97.6%
MPP trackers
3 (BM3) · 4 (BM4)
Warranty
10 years

Specs auto-extracted from the datasheet — confirm against the linked PDF before quoting.

Specifications

Battery input

Battery type
Lithium-ion (self-adaption to BMS)
Battery voltage range
160–800 V
Max. charge / discharge current
50+50 A
Number of battery inputs
2

PV input

Max. PV access power
59800 / 60000 / 70000 / 80000 / 100000 W
Max. PV input power
44850 / 45000 / 52500 / 60000 / 75000 W
Max. PV input voltage
1000 V
Start-up voltage
180 V
MPPT voltage range
150–850 V
Rated PV input voltage
600 V
Max. operating PV current
36+36+36 A (BM3) · 36+36+36+36 A (BM4)
Max. input short-circuit current
55+55+55 A (BM3) · 55+55+55+55 A (BM4)
No. of MPP trackers / strings
3/(2+2+2) (BM3) · 4/(2+2+2+2) (BM4)

AC output

Rated AC input/output active power
29900 / 30000 / 35000 / 40000 / 50000 W
Max. AC apparent power
29900 / 30000 / 35000 / 40000 / 50000 VA
Rated AC input/output current
43.4 / 43.5 / 50.8 / 58 / 72.5 A
Grid voltage / range
230/400 V · 240/415 V, 0.85Un–1.1Un
Grid frequency / range
50 Hz (45–55 Hz)
Grid connection
3L + N + PE
Unbalanced output
100%
Max. continuous passthrough (grid→load)
200 A
Peak power (off-grid)
1.5× rated, 10 s
Power factor adjustment range
0.8 leading to 0.8 lagging
THDi
<3%

Efficiency

Max. efficiency
97.6%
Euro efficiency
97.0%
MPPT efficiency
>99%

General

Operating temperature
−40 to +60 °C (derating >45 °C)
Permissible humidity
0–100%
Permissible altitude
2000 m
Noise
≤65 dB
Surge protection
Type II (DC), Type II (AC)
Protection degree
IP65
Topology
Non-isolated
Cooling
Intelligent air cooling
Dimensions (W×H×D)
527 × 894 × 294 mm
Weight
80 kg
Communication
WiFi, RS485, CAN
Grid standard
AS/NZS 4777.2
Warranty
10 years

Downloads

Highlights

  • High-voltage battery (160–800 V) for higher round-trip efficiency on larger commercial and utility sites.
  • 100% unbalanced output across the three phases.
  • 3 MPP trackers (BM3 frame, to 35 kW) or 4 MPP trackers (BM4 frame, 40–50 kW) with up to 100 A combined battery current across two inputs.
  • AC-coupling to retrofit an existing solar system, plus support for storing energy from a diesel generator.
  • Six charge/discharge time periods for time-of-use and VPP scheduling.

Figures are from the official Deye SUN-29.9/35/40/50K-SG01HP3-AU-BM3/BM4 datasheet — confirm the exact variant against the linked datasheet before quoting or commissioning.