Hybrid inverter Three-phase HV
SG02HP3 Three-Phase HV Hybrid · 60–80 kW
SUN-60/70/80K-SG02HP3-AU-EM6
60–80 kW
High-voltage three-phase hybrid, 60–80 kW. 160–1000 V battery, six MPP trackers, 98.7% peak efficiency and up to 160 A battery current — the top-end HV hybrid for commercial and utility storage.
CommercialUtility
- Rated AC power
- 60 / 70 / 75 / 80 kW
- Phase
- Three (230/400 V, 240/415 V)
- Battery
- HV Lithium-ion, 160–1000 V, up to 80+80 A
- Max. PV input power
- 96–128 kW
- MPP trackers
- 6
- Max. efficiency
- 98.7%
- Parallel
- Up to 10 units
- Warranty
- 10 years
Specs auto-extracted from the datasheet — confirm against the linked PDF before quoting.
Specifications
Battery input
- Battery type
- Lithium-ion (self-adaption to BMS)
- Battery voltage range
- 160–1000 V
- Max. charge / discharge current
- 80+80 A
- Number of battery inputs
- 2
PV input
- Max. PV access power
- 120000 / 140000 / 150000 / 160000 W
- Max. PV input power
- 96000 / 112000 / 120000 / 128000 W
- Max. PV input voltage
- 1000 V
- Start-up voltage
- 180 V
- MPPT voltage range
- 150–850 V
- Rated PV input voltage
- 650 V
- Max. operating PV current
- 36+36+36+36+36+36 A
- Max. input short-circuit current
- 54+54+54+54+54+54 A
- No. of MPP trackers / strings
- 6 / (2+2+2+2+2+2)
AC output
- Rated AC input/output active power
- 60000 / 70000 / 75000 / 80000 W
- Max. AC apparent power
- 60000 / 70000 / 75000 / 80000 VA
- Rated AC input/output current
- 87 / 101.5 / 108.7 / 116.0 A
- Grid voltage / range
- 230/400 V · 240/415 V, 0.85Un–1.1Un
- Grid frequency / range
- 50 Hz (45–55 Hz)
- Grid connection
- 3L + N + PE
- Unbalanced output
- 100%
- Max. continuous passthrough (grid→load)
- 200 A
- Peak power (off-grid)
- 1.5× rated, 10 s
- Power factor adjustment range
- 0.8 leading to 0.8 lagging
- THDi
- <3% (of nominal power)
Efficiency
- Max. efficiency
- 98.7%
- Euro efficiency
- 98.1%
- MPPT efficiency
- >99%
General
- Operating temperature
- −40 to +60 °C (derating >45 °C)
- Permissible humidity
- 0–100%
- Permissible altitude
- 3000 m
- Noise
- ≤65 dB
- Surge protection
- Type II (DC), Type II (AC)
- Protection degree
- IP65
- Topology
- Non-isolated
- Cooling
- Smart cooling
- Dimensions (W×H×D)
- 606 × 927 × 314 mm
- Weight
- 105 kg
- Communication
- RS485 / RS232 / CAN
- Grid standard
- AS/NZS 4777.2
- Warranty
- 10 years
Highlights
- Six MPP trackers (2 strings each) for large, multi-orientation commercial and utility arrays up to 160 kW PV access power.
- High-voltage battery (160–1000 V) with up to 160 A combined charge/discharge current across two inputs.
- 98.7% peak efficiency (98.1% Euro) — the highest in the SUN three-phase hybrid line-up.
- Up to 10 units in parallel for on-grid and off-grid operation, with support for multiple batteries in parallel.
- AC-coupling to retrofit an existing solar system, plus support for storing energy from a diesel generator.
Figures are from the official Deye SUN-60/70/80K-SG02HP3-AU-EM6 datasheet — confirm the exact variant against the linked datasheet before quoting or commissioning.