SG04LP1 Single-Phase Hybrid · 3–6 kW
Hybrid inverter Single-phase LV Flagship

SG04LP1 Single-Phase Hybrid · 3–6 kW

SUN-3/3.6/5/6K-SG04LP1-AU

3–6 kW

48 V low-voltage single-phase hybrid, 3–6 kW. Dual MPPT on the 3.6–6 kW models, up to 16 units in parallel, AC-coupling to retrofit existing PV, and six chargeable time periods. The workhorse residential hybrid.

Residential
Available ratings
3 / 3.6 / 5 / 6 kW — SUN-3K, SUN-3.6K, SUN-5K, SUN-6K-SG04LP1-AU
Rated AC power
3 / 3.6 / 5 / 6 kW
Phase
Single (230 V)
Battery
48 V LFP, up to 135 A
Max. PV input
4.5–9 kW
MPP trackers
1 (3 kW) · 2 (3.6–6 kW)
Max. efficiency
97.6%
Parallel
Up to 16 units
Warranty
10 years

Specifications

Battery input

Battery type
Lead-acid or Lithium-ion (self-adaption to BMS)
Battery voltage range
40–60 V (48 V models)
Max. charge / discharge current
70 / 90 / 120 / 135 A (3 / 3.6 / 5 / 6 kW)
Battery inputs
1

PV input

Max. PV input power
4500–9000 W
Max. PV input voltage
500 V
Start-up voltage
125 V
MPPT voltage range
150–425 V
No. of MPP trackers / strings
1/1 (3 kW) · 2/(1+1) (3.6–6 kW)
Max. operating PV current
18 A (3 kW) · 18+18 A (3.6–6 kW)

AC output

Rated AC power
3000 / 3600 / 5000 / 6000 W
Rated AC current
13 / 15.7 / 21.7 / 26.1 A
Grid voltage / range
230 / 240 V, 0.85–1.1 Un
Grid frequency
50 Hz (45–55 Hz)
Grid connection
L + N + PE
Max. continuous passthrough (grid→load)
35–40 A
Peak power (off-grid)
2× rated, 10 s

Efficiency

Max. efficiency
97.6%
Euro efficiency
96.5%

General

Operating temperature
−40 to +60 °C (derating >45 °C)
Cooling
Natural (3–5 kW) · Intelligent air (6 kW)
Protection degree
IP65
Dimensions (W×H×D)
330 × 433 × 228 mm
Weight
17 kg
Communication
WiFi, RS485, CAN
Grid standard
AS/NZS 4777.2
Warranty
10 years

Highlights

  • AC-coupling retrofit — add storage to an existing grid-tied solar system without replacing the original inverter.
  • Up to 16 units in parallel for both on-grid and off-grid operation, with multiple batteries in parallel.
  • Six charge/discharge time periods for tariff-aware battery scheduling (ideal for time-of-use and Amber).
  • Generator input — supports storing energy from a diesel generator for backup-heavy sites.
  • Colourful touch LCD, IP65 outdoor rating, and arc-fault protection (optional AFCI).

Good to know for AU installs

  • Grid code AS/NZS 4777.2 — set the correct region/grid-protection profile during commissioning.
  • The 3 kW model is single-MPPT; the 3.6, 5 and 6 kW models have two MPP trackers (one string each) for string flexibility.
  • PV current: the documents differ. The June 2026 datasheet gives 18 A operating and 27 A short-circuit current per MPPT. User manual V4.0.0 prints 13 A and 19.5 A. Confirm with Suncloud before designing strings around modules with an operating current above 13 A.
  • Pair with stackable 48 V LFP batteries (e.g. RW-M6.1-B, RW-F10.2, or AI-W5.1-B).

Figures are from the official Deye SUN-(3-6)K-SG04LP1-AU datasheet (June 2026 edition). The per-model MPPT count matches user manual V4.0.0 (October 2025), but the manual’s PV current figures do not (see above). Confirm the exact model variant against the linked datasheet before quoting or commissioning.

Documents

Everything published for the SG04LP1 Single-Phase Hybrid · 3–6 kW — and where something is missing, it says so instead of hiding the row.