SG01HP3 Three-Phase HV Hybrid · 10–25 kW
SUN-10/12/15/20/25K-SG01HP3-AU-AM2
10–25 kW
High-voltage three-phase hybrid, 10–25 kW. 160–700 V battery for higher efficiency, 100% unbalanced output, dual MPPT and up to 10 units in parallel — the entry HV hybrid for commercial storage paired with HV batteries such as BOS-G.
- Available ratings
- 10 / 12 / 15 / 20 / 25 kW — SUN-10K, SUN-12K, SUN-15K, SUN-20K, SUN-25K-SG01HP3-AU-AM2
- Rated AC power
- 9.999 / 12 / 15 / 20 / 25 kW
- Phase
- Three (230/400 V, 240/415 V)
- Battery
- HV Lithium-ion, 160–700 V, up to 50 A
- Max. PV input power
- 15–37.5 kW
- Unbalanced output
- 100%
- Max. efficiency
- 97.6%
- Parallel
- Up to 10 units
- Warranty
- 10 years
Specifications
Battery input
- Battery type
- Lithium-ion (self-adaption to BMS)
- Battery voltage range
- 160–700 V
- Max. charge / discharge current
- 37 A (10/12/15/20K) · 50 A (25K)
- Number of battery inputs
- 1
PV input
- Max. PV access power
- 20000 / 24000 / 30000 / 40000 / 50000 W
- Max. PV input power
- 15000 / 18000 / 22500 / 30000 / 37500 W
- Max. PV input voltage
- 1000 V
- Start-up voltage
- 180 V
- MPPT voltage range
- 150–850 V
- Rated PV input voltage
- 600 V (10–20K) · 700 V (25K)
- Max. operating PV current
- 20+20 A (10K) · 26+20 A (12/15K) · 26+26 A (20/25K)
- Max. input short-circuit current
- 30+30 A (10K) · 39+30 A (12/15K) · 39+39 A (20/25K)
- No. of MPP trackers / strings
- 2/(1+1) (10K) · 2/(2+1) (12/15K) · 2/(2+2) (20/25K)
AC output
- Rated AC input/output active power
- 9999 / 12000 / 15000 / 20000 / 25000 W
- Rated / max. AC apparent power
- 9999 / 12000 / 15000 / 20000 / 25000 VA
- Rated AC input/output current
- 14.5 / 17.4 / 21.8 / 29 / 36.3 A
- Grid voltage / range
- 230/400 V · 240/415 V, 0.85Un–1.1Un
- Grid frequency / range
- 50 Hz (45–55 Hz) · 60 Hz (55–65 Hz)
- Grid connection
- 3L + N + PE
- Unbalanced output
- 100%
- Max. continuous passthrough (grid→load)
- 40 A (10K) · 80 A (12–25K)
- Peak power (off-grid)
- 1.5× rated, 10 s
- Power factor adjustment range
- 0.8 leading to 0.8 lagging
- THDi
- <3% (of nominal power)
Efficiency
- Max. efficiency
- 97.6%
- Euro efficiency
- 97.0%
- MPPT efficiency
- >99%
General
- Operating temperature
- −40 to +60 °C (derating >45 °C)
- Permissible humidity
- 0–100%
- Permissible altitude
- 2000 m
- Noise
- ≤55 dB
- Surge protection
- Type II (DC), Type II (AC)
- Protection degree
- IP65
- Topology
- Non-isolated
- Cooling
- Intelligent air cooling
- Dimensions (W×H×D)
- 408 × 638 × 237 mm
- Weight
- 30.5 kg
- Communication
- WiFi, RS485, CAN
- Grid standard
- AS/NZS 4777.2
- Warranty
- 10 years
Highlights
- High-voltage battery (160–700 V) for higher round-trip efficiency — pairs with an HV battery such as BOS-G.
- 100% unbalanced output across the three phases.
- Up to 10 units in parallel for on-grid and off-grid operation, with support for multiple batteries in parallel.
- AC-coupling to retrofit an existing solar system, plus support for storing energy from a diesel generator.
- Six charge/discharge time periods for time-of-use and VPP scheduling.
Battery pairings
Deye’s AU configuration list pairs the 12–25 kW models with:
- BOS-G (HVB750V/100A-EU + 10 × BOS-GM5.1, 51.2 kWh), or BOS-G Pro (BOS-G-PDU-2 + 10 × BOS-G-Pack5.1) as the alternative. Install indoors (3U-HRACK rack optional) or outdoors in a BOS-G55-Cabinet.
- Two BOS-G or BOS-G Pro clusters (18 packs, 92.16 kWh) on the SUN-25K only. The clusters sit indoors or in two BOS-G55-Cabinets. The optional BOS-G55-Cabinet-AP-C kit joins them onto the inverter’s single battery input.
- GE-F60 outdoor cabinet (61.44 kWh), with the optional GE-F60-AP-A kit.
The SUN-10K is not in that list. Deye’s BOS-G Pro outdoor solution brochure pairs it with a BOS-G40 Pro (8 × BOS-G-Pack5.1, 40.96 kWh) in one BOS-G55-Cabinet, with the BOS-G55-Cabinet-AP-B kit.
The battery current is capped by the inverter’s single battery input: 37 A on the 10–20 kW models and 50 A on the 25 kW.
Figures are from Deye’s SUN-5–25K-SG01HP3-AU-AM2 datasheet (AU, issue 2026-09-03), which this page follows over the September 2025 issue. The 2026 issue changes three things: the SUN-10K is rated 9999 W / 9999 VA (earlier issues print 10000), the grid voltage reads 230/400 V · 240/415 V (earlier: 220/380 V · 230/400 V), and parallel operation is up to 10 units (earlier: 16); Deye’s AU inverter catalogue (v4.3, March 2026) also prints 230/400 V · 240/415 V and 10 units. Pairings are from Deye’s AU indoor/outdoor configuration list (V1.0, 10 Sep 2026) and the BOS-G Pro outdoor solution brochure (AU, V1.0, 7 Sep 2026). The warranty is as listed in Deye’s SUN Series 10-year limited warranty for Australia and New Zealand (V2.17, July 2026, p.2). Confirm the exact variant against the linked datasheet before quoting or commissioning.
Plan & design
Before anything is ordered — sizing, pairing and design decisions for the SG01HP3 Three-Phase HV Hybrid · 10–25 kW.
Pairs with
Install & commission
On the wall, wired, energised and registered — in the order the job actually runs.
Operate & configure
Monitoring, tariffs, work modes — getting the most out of the system after handover.
- Guide Deye system work modes explained intermediate · 6 min read
- Guide Set up Time-of-Use (TOU) on a Deye system intermediate · 6 min read
- Guide Connect a Deye battery to Amber Electric (Deye Copilot) intermediate · 5 min read
- Guide Deye Copilot — setup, settings and AI strategies intermediate · 7 min read
- Guide Connect a logger to Wi-Fi & DeyeCloud beginner · 5 min read
- Guide 4G logger setup beginner · 3 min read
- Guide Deye warranty explained (AU / NZ) beginner · 5 min read
Troubleshoot
Known issues for this model, worst first — and every fault code it can show.
- Check F13 — F13 — grid abnormal / won't reconnect Inverter shows F13 and drops off-grid, or won't start exporting after commissioning.
- Check W04 warning — meter address collision (001 / 002) The inverter raises a W04 warning — often right after enabling Grid Tie Meter2, even on a …
- Check Won't export / nuisance trips after commissioning New install powers up but won't export, or trips intermittently — no obvious hardware faul…
- Info Deye fault (F) code reference The inverter LCD or DeyeCloud shows an F-code (e.g. F13, F55, F58) and you need to know wh…
- Info Logger keeps going offline in DeyeCloud The plant shows offline / stale data in DeyeCloud, or the Wi-Fi logger won't connect to th…
Documents
Everything published for the SG01HP3 Three-Phase HV Hybrid · 10–25 kW — and where something is missing, it says so instead of hiding the row.
System & shared documents
Not specific to the SG01HP3 Three-Phase HV Hybrid · 10–25 kW — these apply across the range and live here once, not copied per model.