Live battery beginner 4 min read Updated 24 Sept 2026

PDU1 vs PDU3 on the AI-W5.1 — and why neither has a screen

What the PDU1 and PDU3 do in an AI-W5.1 stack, the eight LEDs on the PDU faceplate and what each colour means, and where the settings screen actually is — on the inverter, not on the PDU.

The PDU (Power Distribution Unit) is the module that sits on top of an AI-W5.1-B battery stack. It is a breaker, a set of ports and a row of indicator lights — nothing more. No PDU in the AI-W5.1 range has a screen, a touch display or settings buttons. Everything you configure is set on the inverter.

PDU1 vs PDU3 — which stack takes which

PDU3PDU1
Model codeAI-W5.1-PDU3-B-ESSAI-W5.1-PDU1-B
Sits underthe hybrid inverter headnothing — it is the top of its stack
Used forthe main system: inverter + PDU3 + modules + basea battery-only expansion cluster: PDU1 + modules + base
Role in a multi-cluster systemMasterSlave
Built-in breakerTwo-pole moulded case, 250 A, 1000 Videntical

Deye’s PDU3 quick guide gives three wiring modes: PDU3 + PDU3, PDU3 (master) + PDU1 (slave), and PDU3 (master) + external PCS + PDU1 (slave). In every one of them the PDU3 is the master and carries the inverter; a PDU1 stack never has an inverter on top of it.

Stacking order is base → battery modules → PDU → inverter. The PDU goes over the batteries and the inverter goes over the PDU — the PDU is not a plinth, and it is not the thing you look at.

The eight lights on a PDU

The faceplate carries five blue SOC LEDs plus three status LEDs — eight in total, and that is the entire user interface:

IndicatorWhat it shows
5 × blue SOC LEDsBattery state of charge, 20% per light — 20 / 40 / 60 / 80 / 100%
RUN (green)Working
ALARM (yellow)Alarming
ERROR (red)Protecting / fault

Deye’s spec tables write the three status lights as “working, alarming, protecting” while the faceplate labels them RUN / ALARM / ERROR. These are the same three LEDs, not six.

Don’t confuse the PDU’s eight with the battery module’s three. Every stacked AI-W5.1-B module has its own RUN / ALARM / ERROR trio and no SOC arc — only the PDU carries the five-segment SOC display.

The one physical button on the PDU is the BMS switch, used to sequence the system on and off. It is not a settings control and it is not a factory reset.

Where the settings actually are

On the inverter’s front panel — not on the PDU. The inverter carries four indicators, four function keys and an LCD, and that LCD is a touchscreen. From its System Setup screen you reach:

  • Basic Setup
  • Battery Setup
  • Grid Setup
  • System Work Mode
  • Generator port use
  • Advanced function
  • Li-Batt info

Module addresses need no setting at all — modules auto-network, so there is no DIP switch or address to configure anywhere on the stack.

To read detailed per-pack battery status you have two documented routes, and neither is the PDU:

  1. Through the inverter — link the first pack’s PCS port to the inverter’s 485 port, switch the inverter to lithium mode, and read the packs on the inverter display.
  2. Through a PC — connect Deye’s Windows tool to the communication port of any pack.

If someone asks you to “change a setting on the PDU”, the answer is that you can’t. The PDU reports; the inverter controls. Confirm anything you are about to commission against the AI-W5.1-B (PDU1) user manual and the inverter’s own manual.

Cluster limits

A battery-only PDU1 stack takes 1–6 battery modules; the inverter’s own PDU3 stack takes 1–5 (Deye AU brochure, 28 Aug 2026). Up to 6 clusters parallel through the RJ45 IN/OUT daisy chain. Maximum current for a single battery system is 250 A — cable cross-section at least 55 mm². Exceeding 250 A overheats the connectors and cable.

Full figures are on the AI-W5.1 All-in-One BESS page and the AI-W5.1-B battery page; assembly steps are in Stacking AI-W5.1-B battery modules.